Areva MiCom P Pdf User Manuals. View online or download Areva MiCom P Technical Manual. INTRODUCTION The overcurrent relays of the MiCOM P range are AREVA T&D universal overcurrent relays.. P and P relays have been designed to . The overcurrent relays of the MiCOM P range are Areva T&D universal overcurrent relays. MiCOM P, P, P and P relays have.

Author: Tojar Tor
Country: Samoa
Language: English (Spanish)
Genre: Automotive
Published (Last): 2 November 2011
Pages: 97
PDF File Size: 20.21 Mb
ePub File Size: 16.7 Mb
ISBN: 742-9-57962-137-6
Downloads: 23595
Price: Free* [*Free Regsitration Required]
Uploader: Goltigar

The reference is initially set in the factory to ALST.

Insulation and dielectric strength testing Insulation testing may ateva capacitors charged up to a hazardous voltage. Power System Simulator for Testing Protection Relays and Schemes Everything you need for protection scheme testing The is the only instrument with the high power, flexibility and software to perform full.

Areva MiCOM P/P/P/P – Overcurrent Relays. Technical Guide [PDF] – Все для студента

Before working in the terminal strip area, the equipment must be isolated. Displays the total number of re-closings for cycle 3. Displays the peak value for phase C. They can aeva fully integrated to a control system so protection, control, data acquisition and recording of faults, events and disturbances can be made available. The technical data in this Safety Section is typical only, see the technical data section of the relevant equipment documentation for data specific to a particular equipment.

MiCOM P12x/y AREVA T&D. Three phase and earth fault overcurrent relays

Equipment in this category is qualification tested at 5 kV peak, 1. Displays the IA average value demand. In addition, the use of the RS communication port makes it possible to read, reinitialise and change the settings of the relays, if required, from arevq local or remote PC computer loaded with MiCOM S1 software.

  ENFERMEDAD DE VON RECKLINGHAUSEN PDF

Fiber optic communication Where fiber optic communication devices are fitted, these should not be viewed directly. First Numerical overcurrent relay launched in More than devices installed. Press ‘ to confirm your choice.

Design Evaluation Basis of Design This section applies to the design relating to low voltage switchboards. Shows that the delay time type chosen is DMT.

Press ‘ to validate your choice Set the value for the k factor associated with the thermal overload function. Contact fingers of test plugs are normally protected by petroleum jelly, which should not be removed.

Micom p122 software social advice

NO ES b: Displays the total number of reclosings. Select either 50 or 60 Hz. Network Automation Solutions Network Automation Solutions Answers to demands The current demographic growth and the continuous industrial development pose challenges for the current way of producing and distributing electricity. I want amps hwx circuit breaker Siemens Scope This guideline defines the standard tests that all electrical systems and equipment must pass prior to final acceptance by the University.

Comprehensive range of digital protection relays Maximize protection MiCOM 10, 20, 30, 40 Comprehensive range of digital protection relays Make the most of your energy Increase arev availability Maximize energy availability and the profits generated More information.

  KUMITE GATA PDF

It is intended for the use. STORAGEIf relays are not to be installed immediately upon receipt they should be stored in a place free from dust and moisture in their original arsva. Displays the negative sequence component. Displays the IC peak value demand. Choose the baud rate of IEC transmission.

areva p series manual

Choose the rated secondary current of the line CT. Two blocking logic inputs can be configured independently each other to lock any combination of the selected elements i.

This can be done in several ways, for example by inserting between the conductor and the case a plated nickel or insulated ring washer or by using a tin terminals. As soon as an alarm is detected by the relay, that information is considered as more important and the alarm message is then displayed instead of the default value.

When electrical equipment is in operation, dangerous voltages will be present in certain parts of the equipment. The value is the true RMS maximum value. Displays the IB average value arevs.

This fault can arise from broken conductor, mal-operation of one of the switchgear poles, or blowing of a fuse.